首頁  >  產品分類  >  溫度/壓力/應力及校正  >  TEAC  >  TD-SC1 應力型荷重訊號模組

 

·        High-speed sampling (20,000 times/sec. (Resolution: 24bit))

·        EterNet/IP, CC-Link, RS-485 (Communication options)
*The release date of CC-Link and EtherNet/IP is yet to be determined.

·        Various settings by PC, and Display

·        Plug-and-Play TEDS Calibration

 

The TD-9000T is a digital indicator for load management that supports two inputs, load (load cell) and stroke (displacement gauge).
High-speed A/D conversion of 25,000 times/sec and equipped with a 4.3-inch touchscreen monitor in DIN1/4 (92 x 92) size. While being high-end, it is a high-performance model that realizes a low price.
Waveforms during measurement can be checked in real time. Widely usable from daily monitoring to verification of processing data.

 

TD-SC1(D/A) D/A output model TD-SC1(485) RS-485 model

 

Thin and compact design
Compact design (W30 x H85 x D110mm) + lightweight (210g)

With a "thin and compact design" that minimizes the functions, the DIN rail fixing method saves space in the control unit and contributes to the miniaturization of your equipment.

Thin and compact design
Thin and compact design
TEDS calibration

This is an automatic calibration function that saves the trouble of inputting numerical values during equivalent input calibration. Sensor information is read when the power is turned on, and calibration is completed automatically. The rated output value (mV/V) of the strain gauge transducer and the rated capacity value are being recorded in the TEDS memory, and it is a calibration method based on this data.

TEDS calibration
Digital filter

Equipped as standard with 3, 10, 30, 100, 300, 1000 Hz(−6 dB/oct) or Off.
Combined with the moving average (OFF, 2 to 2048), it reduces indicator value unsteadiness.

Rich network

Supporting various fieldbuses; RS-485, CC-Link, EtherNet/IP, etc.

RS-485, CC-Link, EtherNet/IP
Various settings by PC, and Display

Various settings can be made on the PC and set on the TD-SC1 via a USB connection.

Various settings can be made on the PC

Indicated value, comparison judgment (LO / OK / HI / FULL), hold value, and static strain can be displayed.

Indicated value, comparison judgment (LO / OK / HI / FULL), hold value, and static strain
High-speed A/D conversion

Realizing the fastest high-speed sampling of 20,000 times/sec in TEAC signal conditioners.

High-speed A/D conversion
Status indicator

When the load cell is overloaded, the LED lamp lights up to notify you.

Status indicator
Linearization calibration

The linearity of load measurements is improved by increasing the calibration points.
Perform linearization calibration after performing actual load calibration and equivalent input calibration.

Linearization calibration

 

Contact output

3 contact outputs (HI/LO/OK)

 

 

 

 

 

*TD-SC1 (485) only
**TD-SC1 (D/A) only

  • Specifications and appearance are subject to change without notice.
  • Weight and dimensions are approximate.
  • Illustrations in this owner's manual might differ slightly from production models.
Bridge Voltage DC 10 V, 5 V±10% (30mA current maximum, can be used with remote sense)
Signal input range ±5.0mV/V
Equivalent Input/TEDS Calibration range 0.05mV/V - 5.0mV/V
Calibration precision Within 0.1% F.S. (when using 1m standard TEAC Ø8, 6-core shielded cable with 350Ω impedance, 10V BV and 5mV/V setting)
Precision Linearity Within 0.01%F.S. +1 digit (when input is 5mV/V)
Zero drift Within 0.5µV/ºC (Input conversion value)
Gain drift Within ±0.005%F.S/ºC
A/D conversion 24-bit, 20000 times/second
Digital filter Select 3, 10, 30, 100, 300, 1000 Hz(−6 dB/oct) or none
D/A output** 4000 times per second, isolated output, ±1–±10V voltage output (set in 1V steps) and about 1/59000 resolution (when set to ±10 V), or 4–20mA current output and about 1/43000 resolution
TEDS function IEEE1451.4 class 2 mix mode interface
Indicator value Display range −99999 to 99999
Decimal point Display position selectable
Times displayed Select 4, 6, 10 or 20 times/second
Setting items Calibration settings Zero Balancing, TEDS Calibration, Actual Load Calibration, Equivalent Input Calibration
Function settings High limit, low limit, comparison mode, hysteresis, nearly zero, moving average, low pass filter, motion detect, zero tracking, static strain, digital zero, digital offset, zone definition, hold mode, lock, minimum grid, display times, bridge voltage, digital zero limit, clear digital zero, comparison output pattern, select data output**, D/A converter**, remote sense
Hold function Sample hold, peak hold, bottom hold, zone definition hold (peak, bottom)
External input and output signals Input Hold, clear, digital zero (isolated from main unit circuits using a photocoupler)
Output HI, OK, LO open collector output (isolated from main unit circuits using a photocoupler)
RS-485* A+, B–(isolated from main unit circuits using a photocoupler), TRM, SG
Power supply Ratings: 24V DC ±10% 7W
Operating temperature range 0℃ to 40℃
Storage temperature range –20℃ to 60℃
Operating humidity range 85% RH or less (without condensation)
Applicable standards CE marking, FCC (Class A), UL61010-1, UKCA
External dimensions (W×H×D) Approximately 30 mm × 85 mm × 110 mm (without protrusions)
Weight About 210 g
TEAC TD-SC1 型錄
PDF
TEAC TD-SC1 規格
PDF
TEAC TD-SC1 電源端子更改通知
PDF
TEAC TD-SC1 應力荷重訊號模組

相關產品

TD-01 便攜式是一種數字指示器,可與基於應變計的傳感器連接。該裝置將來自傳感器的輸入信號顯示為指標值或圖形顯示,並具有以下特點: 彩色圖形 LCD、高速處理 A/D 轉換器、指標記錄、中斷檢查和對 TEDS 的支持,具有出色的可見性。
TD-700T is a digital indicator to measure and display physical quantity such as load, pressure, and torque working with
The TD-9000T is a digital indicator for load management that supports two inputs, load (load cell) and stroke (displacem