首頁
>
產品分類
>
紅外線熱像儀
>
CHAUVIN ARNOUX
>
CA 1888系列紅外線熱像儀
產品分類
Products
產品分類
Products
CA 1888系列紅外線熱像儀
chevron_right
RayCAm High Resolution Infrared Cameras
The Chauvin Arnous RayCAm C.A 1886 and C.A 1888 high resolution infrared cameras provide thorough thermal analysis with comprehensive parameterization. They incorporate a large TFT screen for easier reading. Temperature sensitivity up to 600 °C and a temperature detection matrix resolution of up to 384 x 288 (C.A 1888). Complete IR-Merge functions (IR image in real image from 0 to 100 %).
Field of view: 20° x 15° (CA1886 740-6470) and 24° x 18° (CA1888 740-6474)
Matrix resolution: 160 x 120 (740-6470) and 384 x 288 (740-6474)
IR and real image merge, 0 to 100%
IP 54 leakproofing
Excellent legibility thanks to its multidirectional screen, even in places where access is difficult
Comfortable handling due to its pistol shape
Automatic detection and indication of hottest/coldest point
Parameter settings affecting measurement:
Adjustable emissivity
Adjustment of measurement distance
Parameters for defining relative humidity and ambient temperature
Parameterizable alarms
Isotherm function
Storage capacity of 1,000 radiometric images organized in 250 folders and back-up on mini-SD card (2GB max.)
Matrix resolution: 160 x 120 (740-6470) and 384 x 288 (740-6474)
IR and real image merge, 0 to 100%
IP 54 leakproofing
Excellent legibility thanks to its multidirectional screen, even in places where access is difficult
Comfortable handling due to its pistol shape
Automatic detection and indication of hottest/coldest point
Parameter settings affecting measurement:
Adjustable emissivity
Adjustment of measurement distance
Parameters for defining relative humidity and ambient temperature
Parameterizable alarms
Isotherm function
Storage capacity of 1,000 radiometric images organized in 250 folders and back-up on mini-SD card (2GB max.)
Supplied with
Delivered in a case with 1 battery charger, 2 batteries, a 2GB mini-SD Card, 1 SD card reader, 1 video cable, RayCAm Report software and a measurement report.
Specifications
Attribute | Value |
Temperature Measurement Range | -20 → +600 °C |
Detector Resolution | 384 x 288pixel |
Display Resolution | 640 x 480pixel |
Application | Thermography |
Model Number | C.A 1888 |
Thermal Sensitivity | ≤0.08°C |
Best Temperature Measurement Accuracy | ±2% + 2 °C |
Focus Type | Manual |
Refresh Rate | 50Hz |
Minimum Focus Distance | 100mm |
Display Size | 3.5in |
Minimum Focus | 100 mm |
Model Number p | C.A 1888 |